Rising Medical Equipment Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Wang Jenny
  • Company Name : Rising Medical Equipment Co., Ltd.
  • Tel : 86-10-51290013
  • Fax : 86-10-59812390
  • Address : Beijing,Beijing,Suite 506, Longguan Zhiye Plaza, Huilongguan, Changping District, Beijing, 102208, China
  • Country/Region : China
  • Zip : 102208

2012 NEW CE CE 6-Parameter Patient Monitor vital signs monitor

2012 NEW CE CE 6-Parameter Patient Monitor vital signs monitor
Product Detailed
Related Categories:Ward Nursing Equipments
8.4aa color TFT display Unique digital SPO technology with excellent measurement interference-free Audible and visual alarm
 

 6 parameter 8.4-inch Vital Sign Patient Monitor (ECG NIBP SPO2 TEMP RESP PR)

 

 

Features:            

8.4” color TFT display Unique digital SPO technology with excellent measurement and interference-free Audible and visual alarms with adjustable alarm range Anti electrosurgical interference and defibrillation Can be connected with LAN to work with central monitoring system Powerful data management and storage capacity Suitable for adult, pediatric and neonatal patient

Standard configuration:            

ECG NIBP SPO2  PR, Thermal printer

Optional:            

RESP, TEMP, 2-TEMP, 2-IBP, ETCO2

Technical Specifications:

ECG:            

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V) Lead selection: I, II, III, avR, avL, avF, V Waveform: 2 ch Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV HR and Alarm Range:Adult: 15 ~ 300 bpmNeo/Ped: 15 ~ 350 bpmAccuracy: ±1% or ±1bpm, which greatResolution: 1 bpmSensitivity: >200uV P-P Differential Input Impedance: >5MΩ CMRR:Monitor: >105dBOperation: >105dBDiagnosis: >85dB Electrode offset potential: 300mV Leakage Current: <10uA Baseline Recovery: <3s after Defi. ECG Signal Range: 8mV(Vp-p) Calibration Signal: 1mV (Vp-p), 5% Accuracy ST Segment measure and alarm: -2.0 ~ +2.0 mV

NIBP:            

Method: Oscillometry Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90Min Measuring Period in STAT Mode: 5 Min Pulse Rate Range: 40 ~ 240 bpm Alarm Type: SYS, DIA, MEAN Measuring and alarm Range Adult Mode:SYS: 40 ~ 270 mmHgDIA: 10 ~ 215 mmHgMEAN: 20 ~ 235 mmHgPediatric ModeSYS: 40 ~ 200 mmHgDIA: 10 ~ 150 mmHgMEAN: 20 ~ 165 mmHgNeonatal ModeSYS: 40 ~ 135 mmHgDIA: 10 ~ 100 mmHgMEAN: 20 ~ 110 mmHgResolution: 1mmHg Over-pressure protection: YES

SPO2:            

Measuring Range: 0 ~ 100% Alarm Range: 0 ~ 100% Resolution: 1% Accuracy: 70% ~ 100%: 2 %0% ~ 69%: unspecified Actualization interval: About 1Sec. Alarm Delay: 10 Sec. Pulse Rate Measuring and Alarm Range: 0~254bpmResolution: 1bpmAccuracy: 2bpmAlarm Delay: 10 Sec.

Optional:    RESP,2-TEMP,2-IBP,ETCO2,Network

ETCO2

2-IBP

Packing List:

Item 

No.

Contents

Qty

Remark

Standard Configuration

1

Main Unit

1

 

2

Power cable

1

 

3

NIBP tube

1

 

4

ECG cable

1

5 lead

5

ECG Electrodes

10

adult

6

SPO2 Sensor

1

adult

7

Cuff

1

adult

8

Packing list

1

 

9

User Manual

1

 

10

Built-in printer

1

 

11

Paper

1

 

2012 NEW CE CE 6-Parameter Patient Monitor vital signs monitor



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.